529_01: Is it possible to combine multiple functions and perform an integration test as one function?

Question:

Is it possible to combine multiple functions and perform an integration test as one function with CoverageMaster?

Answer:

Yes it is possible. CoverageMaster uses an MPU simulator as its execution environment, and performs the same operations as an actual MPU. Therefore, if the test function has called functions (subfunctions), the functions are executed as is. In addition to the test function, coverage of the called functions can be measured for each function. These executed called functions are displayed in the "Other Functions" section of the "Coverage" view.

 