News

  • 2022/09/27
  • NEWS

Product Version Update Information (PROMPT)

Thank you for using Gaio Technology products.
The following Product Update has taken place.

Update Information

[Product name] PROMPT
[Product Version] V2.6
[Release Date] 2022/9/26(Mon)

Update Contents

Function Improvement

• [Alpha Release] Implemented Coverage Measurement for Stateflow Chart Blocks
–Alpha Release has implemented Coverage Measurement for Stateflow Chart Blocks.
Coverage Measurement for Stateflow Chart Blocks is set to OFF by default.
It can be enabled in the Creation Options.

• An Option has been added to set a timeout for Model Analysis prior to Creation.
–It is now possible to set a Timeout for the Analysis Time as a fraction of the full process Timeout time.
If Model Analysis does not complete within the desired time, setting the Model Analysis Timeout
allows for the Analysis to be terminated and the results obtained to that point are used to create Test Data.

• An Option has been added to enable retention of Test Cases that do not contribute to Coverage Improvement.
–When Creating and Importing Tests, Test Cases which do not contribute to Test Coverage
and those which fail in Simulation can be retained in the Test Data.

• Speed Improvement for MATLAB R2021a
–Data Creating Processing Speed for Model Analysis with MATLAB R2021a has been improved.

Improved Useability

• Test Data Output Function Specification Improved (Data Type is respected.)
–Firstly, PROMPT creates a Waveform based on the Signal Template.
This is then converted to the appropriate Data Type by the Size-Type Subsystem, then input into the Test Target.
Previously, the Test Data Output used the raw data without adjustment.
Now, the Data is adjusted to the appropriate Data Type for the Target Signal before use.

• Handling of S-Functions inside Charts is improved.
–S-Functions within Charts are no longer detected as Supporting Blocks.
Previously, if a Model included Charts, both the Charts and the S-Functions within them
were treated as Unsupported Blocks in the Coverage Measurement Results and Unsupported Code Reports.
From now on, only the Charts will be treated as Unsupported Blocks in Coverage Measurement Reports and Unsupported Code Reports.

• Web Browser-Ready Manual
–A specific Contents Frame has been added.
The PROMPT Manual can now be viewed from Web Browsers.

Restrictions

• Restriction ID5 has been partially reduced.

• Restriction ID has been lifted.

• Restrictions ID962,ID996, ID894, ID940 have been added.