News

  • 2023/07/18
  • NEWS

Product Version Update Information (Coverage Master winAMS/CasePlayer2)

Thank you for using Gaio Technology products.
The following Product Update has taken place.

Update Information

[Product name] Coverage Master winAMS
[Product Version] R9.0
[Release Date] 2023/7/18

*ISO 26262 2nd Edition/IEC 61508 Functional Safety Certified Version is planned for March 2024.

Update Contents

Additional Functionality

• Windows 11 Compatibility
– Windows 11 added to Compatible Operating Systems

• Multi-Session Capability
– Tools using Multi-Session capabilities can be operated simultaneously.
Coverage Master winAMs installed on a Windows Server can be used simultaneously by multiple users.
In this case, one license will be used by each user.
– If an exclusion error occurs during CLI operation, the Return Status can be optionally set to 32 (lockstatus)

Improved Usability

• Improved operation when used with multiple displays
– Corrected a fault where the check box for showing the common stub list in the Stub Settings screen was not responsive when the Coverage Master winAMS GUI was being used in a subdisplay.
– Corrected a fault where a dialog box was not shown after switching back from subdisplay to single display.
– Corrected a fault where Coverage View and some CSV related data were shown in the main display when the Coverage Master winAMS GUI was being used in a subdisplay.

• Improved performance and stability of Simulator Operation
– When executing a test, if [Automatic Start] and [Automatic Stop] are both selected in the [Startup Settings] screen, the simulator is executed using the LIX lite GUI which has no debug functionality.
In this case, to improve the performance and stability of the simulator, messages other than Error Messages are not shown in the LIX screen during the test.
Also, when testing using CLI or Silent CLI, the LIX is used to run the simulator with no Debug functionality. Similarly, no messages other than Error Messages are output.

Improvements to the Manuals

• Known Restrictions have been added. (For the General Microcontroller model)
– When running a General executable object, if the C specification is GNU-C or C99, static functions not called in either case are not converted to executable objects. This limitation has been documented.

Added Functionality (Only for Customers using the MBT Option)

• Additional MATLAB versions supported.
– Support for MATLAB R2022a has been added.

• Windows 11 Compatibility added
– Windows 11 added to Compatible Operating Systems

• Multisession Environment Compatibility added
– Windows Multisession Environment Compatibility added

PROMPT (Sold Separately) Implemented
– Support has been added for PROMPT format CSV fields in the [Test Data AD/DA Conversion] Function
PROMPT format CSV files can be used as input for the MBT Option.
Also, Test Data created using the MBT Option can be output as PROMPT format CSV and used as input data for PROMPT.

• Embedded Coder Information is now compatible with automatic mapping.
– Embedded Coder Information can now be used in the [I/O Mapping] function.

• I/O Mapping is now possible using Signal Variable List files (CSV files).
– In the [I/O Mapping] function, CSV files can can now be prepared and used as Signal Variable List files.

Improved Functionality (Only for Customers using the MBT Option)

• 64bit data types have been implemented
– Models (int64/uint64) and code (long long/unsigned long long) using 64bit data types are now supported.

• Improved Evidence functionality for models that do not output Signal Data.
– Signals that do not output MILS Results or Execution Logs now cause output of "contains empty signal" in the comparison results.

• Functional Improvement when there is no Input Data.
– An error is now output if the MILS Execution function does not have any input data.

Update Information

[Product name] CasePlayer2
[Product Version] R9.0
[Release Date] 2023/7/18

*ISO 26262 2nd Edition/IEC 61508 Functional Safety Certified Version is planned for March 2024.

Update Contents

Additional Functionality

• Windows 11 Compatibility
– Windows 11 added to Compatible Operating Systems

• Multi-Session Capability
– Tools using Multi-Session capabilities can be operated simultaneously.
CasePlayer2 installed on a Windows Server can be used simultaneously by multiple users.
In this case, one license will be used by each user.
– If a exclusion error occurs during CLI operation, the Return Status can be optionally set to 32 (lockstatus)

Improved Usability

• Improved operation when used with multiple displays
– Corrected a fault where the check box for showing the common stub list in the Stub Settings screen was not responsive when the Coverage Master winAMS GUI was being used in a subdisplay.
– Corrected a fault where the dialog display content was corrupted if rthe display was changed to one with a resolution different to the display showing the Tool Window.