News

  • 2026/03/16
  • NEWS

Product Version Update Information (CMW ARM/RX/RH850/RISC-V/TriCore/MicroBlaze Series)

Thank you for using Gaio Technology products.
The following product update has taken place.

Update Information

[Product Name]
CoverageMaster winAMS

[Target Microcontroller]
Simulator Engine : System-G(standard)
ARM Cortex-A5/A7/A8/A9/A12/A15 *1 *2
ARM Cortex-M0/M0+/M1 *2
ARM Cortex-M3 *2
ARM Cortex-M4 *2
ARM Cortex-R4/R4F/R5/R5F *2

Simulator Engine : SX(High Speed)
ARM Cortex-A53/A57(AArch32) *2 *3
ARM Cortex-A53/A57(AArch32/64) *2 *3
ARM Cortex-A35/A72(AArch32) *2 *3
ARM Cortex-A35/A72(AArch32/64) *2 *3
ARM Cortex-A55/A75/A76(AArch64) *2 *3
ARM Cortex-A65/A78/A78AE(AArch64) *2 *3
ARM Cortex-R52 *2 *3
ARM Cortex-R7 *2 *3
ARM Cortex-R4/R4F/R5/R5F *2 *3
ARM Cortex-M33 *2 *3
ARM Cortex-M23 *2 *3
ARM Cortex-M55 *2 *3
ARM Cortex-R4/R4F/R5/R5F (Sanitizer Limited Edition) *3
ARM Cortex-M7 *3
RENESAS RXv2 *3
RENESAS RXv3 *3
RENESAS RH850(G4) *3
RENESAS RH850 *3
RISC-V(RV32) *3
RISC-V(RV64) *3
Infineon TriCore *3
Xilinx MicroBlaze *3
 

Update Contents

OMF Converter ArmOmf : V3.0.0.0

Compiler Version Support

• The following compilers are supported.
Target compiler :ARM compiler(armclang.exe) V6.22.2/V6.24

Improved Functionality

Version Upgrade Details 1 (The above *2 applies)
• We have made the following performance improvements.
-Improved the processing performance of the OMF converter.
-We have reduced the size of XLO files output by the OMF Converter.
-The memory width handled by the OMF converter has been expanded from 32-bit to 64-bit.
This improvement prevents memory reallocation errors during OMF conversion of large objects.


Version Upgrade Details 2 (The above *2 applies)
• We have enabled warnings for optimized variables. The variables indicated in this warning may have limitations preventing their values from being correctly set or referenced in the coverage master winAMS, as their placement has been optimized.

Version Upgrade Details 3 (The above *2 applies)
• The following conversion options have been added.
-[-select_list list file]
Added an option to narrow down the source code subject to debug information conversion. Multiple targets can be specified with a single option.

-[-warnmax Maximum number of warnings displayed]
You can now set the maximum number of warnings displayed by the OMF Converter in the Message View of Coverage Master winAMS.

-[-msgfile message storage file]
Added an option to save OMF converter messages to a file.


Version Upgrade Details 4 (The above *1 applies)
• Added EnaBigBitfield to the project options in CoverageMaster winAMS. Select this when using big-endian.

ARM Cortex-A53/57(AArch32) processor model hsnatc : V1.09.0
ARM Cortex-A53/57(AArch64) processor model hsnaqc : V1.10.0
ARM Cortex-A35/72(AArch32) processor model hsnatk : V1.04.0
ARM Cortex-A35/72(AArch64) processor model hsnaqk : V1.04.0
ARM Cortex-A55/75/76(AArch64) processor model hsnaqf : V1.06.0
ARM Cortex-A65/78/78AE(AArch64) processor model hsnaqj : V1.04.0
ARM Cortex-R52 processor model hsnate : V1.07.0
ARM Cortex-R7 processor model hsnatd : V1.09.0
ARM Cortex-R4/R4F/R5/R5F(SX) processor model hsnat7 : V1.10.0
ARM Cortex-M33 processor model hsnatg : V1.06.0
ARM Cortex-M23 processor model hsnath : V1.03.0
ARM Cortex-M55 processor model hsnati : V1.04.0
ARM Cortex-R4/R4F/R5/R5F(Sanitizer Limited Edition) processor model hsnat7 : V1.10.0
ARM Cortex-M7 processor model hsnatb : V1.09.0
RXv2 processor model hsnhtc : V1.06.0
RXv3 processor model hsnhtd : V1.05.0
RH850(G4) processor model hsnvt5 : V1.07.0
RH850 processor model hsnvt4 : V1.12.0
RISC-V (RV32) processor model hsnwt1 : V1.04.0
RISC-V (RV64) processor model hsnwq1 : V1.02.0
TriCore processor model hsnkt1 : V1.11.0
MicroBlaze processor model hsnzt1 : V1.02.0


Improved Functionality

Version Upgrade Details (The above *3 applies)
• We have implemented a fix for the issue where test execution via Silent CLI and CLI stops midway on the affected processor model. Even if an error occurs during a test, the simulator will continue processing appropriately to the next test without stopping. When used in conjunction with Coverage Master winAMS R11.0 or later (*), it enhances the reliability of test automation in CI/CD environments.
*Scheduled for release by the end of December 2026 (with functional safety certification obtained)